GLI L4-2.0L Turbo (BPY) (2008)
The linkage - A - must move approximately 300 mbar and be at approximately 700 mbar at end position.
Actuator lift is approximately 10 mm.
‹› If the pressure cannot be raised with the (VAS 6213) or the pressure drops immediately, check the (VAS 6213) and connecting hoses for leaks. If
no malfunction can be found: Replace the vacuum diaphragm. Refer to --> [ Turbocharger Vacuum Diaphragm ] See: Service and Repair.