volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Turbocharger Vacuum Diaphragm, Checking|Page 3110 > < Turbocharger Vacuum Diaphragm, Checking|Page 3108
Page 2
background image

If the specification was obtained:

Checking Voltage supply

-

Using a multimeter, check the Wastegate Bypass Regulator Valve N75 electrical harness connector terminal 1 to Ground (GND).

Wastegate Bypass Regulator

Measure to

Valve N75 electrical harness
connector terminal
1

Engine Ground (GND)

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

If the specified value was not obtained:

-

Check the wiring from the Wastegate Bypass Regulator Valve N75 electrical harness connector terminal 1 to the Engine Component Power
Supply Relay J757 socket 2/87 for a open circuit or a short circuit to Ground (GND).

-

Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-

If necessary, repair the wiring connection.

If no malfunctions are found in the wiring:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box.

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) J220.

-

Using a multimeter, check the Wastegate Bypass Regulator Valve N75 electrical harness connector terminal 2 to Motronic Engine Control Module
(ECM) J220 electrical harness connector T60 terminal 4 for an open circuit.

Wastegate Bypass Regulator

Motronic Engine Control Module

Turbocharger Vacuum Diaphragm, Checking|Page 3110 > < Turbocharger Vacuum Diaphragm, Checking|Page 3108