16-pin electrical connection, T16f - C -

1

-

Left Temperature Door Motor V158, cold

2

-

Left Temperature Door Motor V158, warm

3

-

Defroster Door Motor V107, closed

4

-

Defroster Door Motor V107, open

5

-

Central Air Door Motor V70, upper body outlet

6

-

Central Air Door Motor V70, footwell

7

-

Fresh/Recirculating Air Door Motor V154, recirculated air activation

8

-

Fresh/Recirculating Air Door Motor V154, fresh air activation

9

-

Air Flow Door Motor V71, open

10

-

Air Flow Door Motor V71, close

11

-

Right Temperature Door Motor V159, cold

12

-

Right Temperature Door Motor V159, warm

15

-

Fresh Air Blower V2 (PWM activation)

16

-

Fresh Air Blower V2, return message signal