GLI L4-2.0L Turbo (CCTA) (2008)
Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
Diagnostic Procedures
Ambient Air Temperature Sensor, Checking
Special tools, testers and auxiliary items required
‹› multimeter.
‹› Wiring diagram.
Test procedure
-
Perform a preliminary check to verify the customers complaint. Refer to --> [ Preliminary Check ] See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Preliminary Check
Start diagnosis
-
Connect the scan tool.
-
Engine MUST be at room temperature.
-
Turn the ignition switch ON.
-
Using the scan tool, check the ambient air temperature:
-
Turn the ignition switch OFF.
If the specified value was obtained:
-
Fault may be intermittent. Check for proper connection, damaged wiring or loose terminals.
‹› The reading will default to 419 °F if the circuit is open or shorted to ground. The display on the cluster will read 3 dashes.
If the specified value was Not obtained:
Checking internal resistance
-
Disconnect the Ambient Air Temperature Sensor (G17) electrical harness connector.
-
Using a multimeter, check the Ambient Air Temperature Sensor (G17) terminals 1 to 2 for resistance.
Use the chart below for the specified values:
Specified values: