| Move operating rod of throttle valve positioner -V60--arrows- radially. |
Specification: Max. 2.4 kΩ |
Note Whilst operating rod of throttle valve positioner -V60- is slowly being retracted fully (overrun position) by actuating hand-operated vacuum pump with accessories -V.A.G 1390/-, resistance value must decrease constantly at the same time. |
|
|
|