Automatic gearbox 096
Performing self-diagnosis
Fault table

Notes:

  • ◆ All the possible faults which are recognised by the automatic gearbox control unit -J217- and displayed on the V.A.G 1551 with the printer switched on when the fault memory is interrogated, are listed below grouped according to the fault code number.
  • ◆ If fault occur only occasionally or if the fault memory was not erased after rectifying the faults, these faults will be displayed as "sporadic faults" for a stipulated period of time =>Gearbox control unit fault recognition, Page 01-3.
  • ◆ If faulty components are detected during fault memory interrogation, additionally test wiring to components for short and open circuits according to the current flow diagram =>Golf 1992 ▸, Vento 1992 ▸Current flow diagram, Electrical fault finding and Fitting locations binder.
  • ◆ The fault code is printed out in the "rapid data transfer" mode only when the printer of V.A.G 1551 is switched on.
    Example: Fault code (5-position) 65535

Output on printer
V.A.G 1551

 

No fault recognised!

If "No fault recognised" appears after performing repairs, the self-diagnosis is completed.
In the event that the automatic gearbox does not operate properly despite self-diagnosis, carry out repairs as per fault finding programme.
=> "Fault finding, Power transmission" binder, No. 14

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00258

 

Open circuit or short to earth

- Check wiring and connections according to CFD2)

Solenoid valve 1 -N88-

 

Solenoid valve 1 -N88- defective

- Read measuring value block ; display group number 04

 

Open circuit1)
Short to earth1)

 

 

- Perform electrical tests =>from page 01-69

00260

 

Open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 2 -N89-

 

Solenoid valve 2 -N89- defective

- Read measuring value block ; display group number 04

 

Open circuit1)
Short to earth1)

 

 

- Perform electrical tests =>from page 01-69

00262

 

Open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 3 -N90-

 

Solenoid valve 3 -N90- defective

- Read measuring value block ; display group number 04

 

Open circuit1)
Short to earth1)

 

 

- Perform electrical tests =>from page 01-69

1)    One of these displays appears in addition to relevant component.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00264

 

Open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 4 -N91-

 

Solenoid valve 4 -N91- defective

- Read measuring value block ; display group number 04

 

Open circuit1)
Short to earth1)

 

 

- Perform electrical tests =>from page 01-69

00266

 

Open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 5 -N92-

 

Solenoid valve 5 -N92- defective

- Read measuring value block ; display group number 04

 

Open circuit1)
Short to earth1)

 

 

- Perform electrical tests =>from page 01-69

00268

 

Open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 6 -N93-

 

Solenoid valve 6 -N93- defective

- Read measuring value block ; display group number 02

 

Open circuit1)
Short to earth1)

 

 

- Perform electrical tests =>from page 01-69

1)    One of these displays appears in addition to relevant component.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00270

 

Open circuit or short to earth

- Check wiring and connections according to CFD 2)

Solenoid valve 7 -N94-

 

Solenoid valve 7 -N94- defective

- Read measuring value block ; display group number 04

 

Open circuit1)
Short to earth1)

 

 

- Perform electrical tests =>from page 01-69

00281

 

Open circuit in wiring

- Check wiring and connections according to CFD

Road speed sender -G68-

 

Road speed sender -G68- defective

- Read measuring value block , Fig. 8

 


No signal

 

Input gear, impulse wheel loose

- Renewing input gear => Removing and installing input gear, Page 39-8

1)    One of these displays appears in addition to relevant component.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00293

 

Open circuit in wiring

- Check wiring and connections according to CFD 3)

Multifunction switch -F125-

 

Multifunction switch -F125- defective

- Read measuring value block ; display group number 01

 

Undefined switch state

 

 

- Perform electrical tests =>from page 01-18, Fig. 7

00300

 

Open circuit in wiring

- Check wiring and connections according to CFD 2)

Gearbox oil temperature sender -G93-1)

 

Gearbox oil temperature sender -G93- defective

- Read measuring value block ; display group number 05

 

No fault type recognised

 

 

- Perform electrical tests =>from page 01-69

1)    A faulty ATF temperature sender is indicated.

2)    First check connections for contact corrosion or water ingress and renew if necessary. If solenoid faults are displayed then especially check the 10 pin connector on gearbox between valve body conductor strip and wiring loom.

3)    First check connectors for contact corrosion or water ingress and renew if necessary.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00518

 

Open or short circuit

- If in addition fault 00638 is displayed, then rectify this first
Check wiring and connections according to CFD

Throttle valve potentiometer -G69-

 

Throttle valve potentiometer -G69- defective

- Read measuring value block

 

Signal outside tolerance

 

On vehicles from 01.93 with 6-cylinder or 4-cylinder engine with Simos injection and ignition system, the throttle valve potentiometer -G69- signal is directed via engine control unit to gearbox control unit - engine control unit defective

- On vehicles from 01.93 with 6-cylinder or Simos engine, renew engine control unit
=> Repair group 24 or 2501-44

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00529

 

Open circuit in wiring

- Check wiring and connections according to CFD

Speed information missing

 

 

- Read measuring value block =>page

00532

 

Battery defective

- Test battery voltage

Supply voltage

 

Insufficient system voltage for valves

- Read measuring value block

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00545

 

Open circuit or short earth

- Check wiring and connections according to CFD

Engine/gearbox electrical connection

 

No connection engine/gearbox control unit

- Read measuring value block =>page

 

Open circuit1)
Short to earth1)

 

 

- Bring system to basic setting

00596

 

10 pin connector between valve body conductor strip and wiring loom

- Check wiring and connections according to CFD

Short circuit between valve lines

 

Conductor strip to valve body defective

- Perform electrical tests => from page 38-36

1)    One of these displays appears in addition to relevant component.

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00638

 

Open circuit or short to earth

- Check wiring and connections according to CFD

Engine/gearbox electrical connection 2

 

No connection engine/gearbox control unit

- Read measuring value block =>page

 

No signal

 

 

- Bring system to basic setting

00641

 

Gearbox becomes too hot, max. 148°C. If ATF temperature is too high, gearbox shifts down into next lower gear.

- Check ATF level ; display group number 05; read off ATF temperature

ATF temperature

 

Trailer load of vehicle too high

 

 

Signal too large

 

ATF level not in order

 

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

00652

Gear monitoring

 

Electrical/hydraulic fault

Clutch or valve body defective

- Read measuring value block ; display group number 04 and establish by driving in which gear the fault occurs

Implausible signal

 

 

 

00660

 

Open circuit in wiring

- Check wiring and connections according to CFD

Kickdown switch/throttle valve potentiometer

 

Throttle valve potentiometer -G69- defective

- Perform repairs as described in "Rectifying fault" 00518 -Throttle valve potentiometer -G69-

 

Implausible signal

 

Kickdown switch -F8- defective

- Read measuring value block =>page

Output on printer
V.A.G 1551

Possible cause of fault

Rectifying fault

65535

 

 

- Renew control unit

Control unit defective

 

Control unit -J217- defective

- Bring system into basic setting

Notes:

The control unit -J217- should not be renewed until the possible cause of the fault has been determined and the following faults have been rectified:

  • ◆ mechanical faults
  • ◆ hydraulic faults
  • ◆ all affected electrical/electronic components and cable connections.