volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Refrigerant R134a > < Pressure and boiling point
Vapour pressure table for refrigerant R134a
Vapour pressure table for refrigerant R134a
The vapour pressure table for each refrigerant is published in the literature for refrigeration engineers. This table shows the vapour pressure exerted on the liquid column in the container for a given temperature of the container.
Since a characteristic vapour pressure table is known for every refrigerant, one can determine what refrigerant is present by measuring pressure and temperature.
  Note
Absolute pressure means that 0 bar corresponds to an absolute vacuum. The normal ambient pressure (positive pressure) corresponds to 1 bar absolute pressure. On most pressure gauges, a reading of 0 bar corresponds to an absolute pressure of one bar (which is confirmed by the existence of a -1 bar marking beneath the 0 scale marking).
   
Temperature in ° CPressure in bar (positive pressure) R134a
-45-0.61
-40-0.49
-35-0.34
-30-0.16
-250.06
-200.32
-150.63
-101.00
-51.43
01.92
52.49
103.13
153.90
204.70
255.63
306.70
357.83
409.10
4510.54
5012.11
5513.83
6015.72
6517.79
7020.05
7522.52
8025.21
8528.14
9031.34

   

Refrigerant R134a > < Pressure and boiling point