volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Checking ignition transformer > < Checking and adjusting ignition timing
1AV fuel injection and ignition system
Servicing ignition system
Checking Hall sender

Special tools, testers, measuring instruments and auxiliary items required

  • ◆ Test box V.A.G 1598/18
  • ◆ Hand multimeter V.A.G 1526 or multimeter V.A.G 1715
  • ◆ Adapter set V.A.G 1594
  • ◆ Current flow diagram

Test conditions

  • ● Fault on Hall sender recognised by self diagnosis

Test sequence

 
V28-0672
  • ‒ Pull connector off Hall sender (distributor).
  • ‒ → Connect multimeter to measure voltage using aux. cables from V.A.G 1594 to the outer contacts of the connector.
  • ‒ Switch on ignition.
         Specification: min. 9 V
  • ‒ Switch off ignition.
 
N24-0137
  • ‒ → Connect test box V.A.G 1598/18 to control unit wiring loom.
  • ‒ Check wiring between test box and connector for open circuit according to current flow diagram.
         Contact 1+socket 17
         Contact 2+socket 13
         Contact 3+socket 8
         Wire resistance: Max. 1.5 ω
  • ‒ Additionally check wires for short to one another.
         Specification: ∞ω

If no wiring fault is detected and voltage was present between contacts 1+3:

  • ‒ Renew Hall sender , item 6 .

If no wiring fault is detected and no voltage was present between contacts 1+3:

  • ‒ Renew engine control unit
    => Page 24-11 , item 28

Checking ignition transformer > < Checking and adjusting ignition timing