Pull connector off coolant temperature sender (G62).
-
‒ →
Set Digital potentiometer V.A.G 1630 -side A- to 3.8 kω
(corresp. approx. 10 °C) and connect to above connector using aux. cables from V.A.G 1594.
-
‒ Operate starter.
The LED must light up for approx. 1...4 seconds (Repeatedly starting engine reduces LED light up time).
-
‒ Set Digital potentiometer to 2.6 kω (corresponds to approx. 20 °C).
-
‒ Operate starter.
The LED must not light .
Otherwise:
-
‒ Reconnect to cold start valve connector.
-
‒ Carry out electrical check, test step 3
, if necessary renew Digifant control unit (J169).
Checking cold start valve (N17)
-
● Voltage supply OK.
-
● Cold start valve connector attached.
-
● Digital potentiometer connected to coolant temperature sender connector.
|