volkswagen Workshop Repair Guides

Volkswagen Golf Workshop Service and Repair Manuals

Checking intake air temperature sender > < Checking throttle valve potentiometer
Mono Motronic injection and ignition system
Mono-Motronic injection and ignition system
Checking coolant temperature sender

Special tools, testers and auxiliary items

  • ◆ Fault reader V.A.G 1551 or vehicle system tester V.A.G 1552 with
         ▸ 07.93: Cable V.A.G 1551/1
         08.93 ▸: Cable V.A.G 1551/3
  • ◆ Test box V.A.G 1598/18
  • ◆ Hand multimeter V.A.G 1526 or multimeter V.A.G 1715
  • ◆ Adapter set V.A.G 1594
  • ◆ Current flow diagram

Test sequence

  • ‒ Connect fault reader V.A.G 1551 (V.A.G 1552) and select engine electronics control unit (address word 01); carry out selection at idling.
 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Input 08 for "Read measured value block" function and confirm with Q.
 
→ Indicated on display:
Read measured value block     HELP
Input display group number XX

Engine code ABD ▸ 01.93:

  • ‒ Input 00 for "Display group number" and confirm with Q.
 
→ Read-off figure displayed in display zone 1.
Read measured value block     0     ⇒
     1     2     3     4     5     6     7     8     9     10
  • ‒ Determine possible cause of fault according to the table and continue with appropriate check.
  • Engine code ABD 02.93 ▸ ABU, AEA:

    • ‒ Input 01 for "Display group number" and confirm with Q.
    • ‒ Note intake air temperature figure in display zone 2.
    • ‒ Determine possible cause of fault according to the table and continue with appropriate check.

    Display

    Cause

    Continuation of check

    app. 240 or
    app. -50 °C

    Open circuit or short to positive

    => Page 24-66

    App. 0 or app. 130°C

    Short to earth

    => Page 24-67

    Between 8...230 or app. coolant temperature1)

    ---

    Only if spora-
    dic faults
    have been
    detected:2)
    => Page 24-68

         1)     If a temperature is displayed which deviates greatly from the ambient temperature of the sender, check sender wiring for transfer resistances. For display group 0:
              125 corresponds to approx. 20 °C
              25 corresponds to approx. 85 °C

     
    N24-0146

         2)     Check is only possible when the engine is cold.

    Continuation of check when display = approx. 240 or approx. -50°C:

    • ‒ → Pull 4 pin connector -1- of coolant temperature sender (G62) -2-.
    • ‒ Bridge connector contacts 1+3 with aux. cables from V.A.G 1594 and observe display.

    Display 0 or approx. 130 ° C:

    • ‒ Replace coolant temperature sender -2-.

    Display approx. 240 or approx. -50 ° C:

    • ‒ Press ⇒ button.
    • ‒ Input 06 for "End output" and confirm with Q.
    • ‒ Switch off ignition
     
    N24-0160
    • ‒ → Connect test box V.A.G 1598/18 to control unit wiring loom.
    • ‒ Check wire between test box socket 42+4 pin connector contact 3 for open circuit according to current flow diagram.
           Wire resistance: Max. 1.5 ω
    • ‒ Additionally check wire for short to battery positive.
           Specification: ∞ω
    • ‒ Check wire between test box socket 17+4 pin connector contact 1 for open circuit according to current flow diagram.
           Wire resistance: Max. 1.5 ω

    If no fault in wire is detected:

    • ‒ Renew Mono Motronic control unit (J257)
      , item 2 .

    Continuation of check when display = 0 or approx.130 °C:

     
    N24-0147
    • ‒ → Pull 4 pin connector -1- of coolant temperature sender (G62) -2-.

    Display approx. 240 or approx. -50 ° C:

    • ‒ Replace coolant temperature sender -2-.

    Display 0 or approx. 130 ° C:

    • ‒ Press ⇒ button.
    • ‒ Input 06 for "End output" and confirm with Q.
    • ‒ Switch off ignition
    • ‒ Pull connector off Mono Motronic control unit.
    • ‒ Check wire between control unit connector and 4 pin connector contact 3 for short to wire contact 1 and to vehicle earth, according to current flow diagram.
           Specification: ∞ω

    If no fault in wire is detected:

    • ‒ Renew Mono Motronic control unit (J257)
      , item 2 .

    Continuation of check when display = coolant temperature:

    Functional check of sender

    Display group 00:

       
      → Observe displayed figure in display zone 1. The displayed figure must
           decrease uniformly without interruption.
      Read measured value block     0     ⇒
           1     2     3     4     5     6     7     8     9     10

      Display group 01:

         
        → Observe coolant temperature figure in display zone 2. The temperature figure must
             Increase uniformly and without interruption.
        Read measured value block 1     ⇒
             1     2     3     4

        Notes:

        • ◆ If the display on fault reader jumps by 2...5 °C, it is a control unit fault and not caused by a defective sender.
        • ◆ If irregular engine running occurs in certain temperature ranges and the temperature figure does not increase without interruption, the temperature signal is temporarily interrupted and the sender must be renewed.
        • ‒ Press ⇒ key.
        • ‒ In put 06 for "End output" and confirm with Q.

        Checking intake air temperature sender > < Checking throttle valve potentiometer