volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Removing and installing batteries for the main key with radio wave remote control > < Matching ignition keys to radio wave remote control
Body self-diagnosis
Self-diagnosis for central locking
Radio wave remote control functional variants


Channel number

Significance

Measured value

03

Auto lock/unlock: Vehicles will be locked when a speed of 15 km/h is reached

on=1
off= 0

04

Auto lock/unlock: Vehicles will be unlocked when the ignition key is withdrawn from the ignition lock

on=1
off= 0

05

IM switch-off: Interior monitoring is activated or deactivated by operating central locking closed twice

on=1
off= 0

06

Horn sounds when unlocking: Confirmation signal when unlocking1)

on=1
off= 0

07

Horn sounds when locking: Confirmation signal when locking1)

on=1
off= 0

08

Turn signals flash when unlocking: Unlocking is confirmed by turn signals flashing twice

on=1
off= 0

09

Horn sounds when locking: Locking is confirmed by turn signals flashing once

on=1
off= 0

10

Setting for alarm horn: Programming the horn operation when the alarm is triggered appropriate to the legislation of the countries

1= Rest of Europe
2= Germany
3= Great Britain

1)     No longer allowed according to German legislation.

The matching shown here is only an example.

 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Press keys 1 and 0 (10 selects function "Adaption").
 
→ Indicated on display:
Rapid data transfer     Q
10 - Adaption
  • ‒ Confirm entry with the Q key.
 
→ Indicated on display:
Adaption    
Enter channel number XX
  • ‒ Press keys 0 and 8 (channel number 08 switches the turn signals on or off when unlocking).
 
→ Indicated on display:
Channel 8     Adaption     1     ⇒
Unlock     Flashing     on    
  • ‒ Press ⇒key.
 
→ Indicated on display:
Channel 8.........Adaption     1     ⇒
Enter adaption value XXXXX
  • ‒ Press ⇒key.
  • ‒ Press key 0 five times (e.g. 00000).
 
→ Indicated on display:
Channel 8.........Adaption     0     Q
Enter adaption value 00000
  • ‒ Confirm entry with the Q key.
 
→ Indicated on display:
Channel 8     Adaption     0     Q
Unlock     Flashing     off    
  • ‒ Confirm entry with the Q key.
 
→ Indicated on display:
Channel 8     Adaption     0     Q
Store amended value?
  • ‒ Confirm entry with the Q key.
 
→ Indicated on display:
Channel 8     Adaption     0     ⇒
Amended value is stored
  • ‒ Press ⇒key.
 
→ Indicated on display:
Rapid data transfer     HELP
Select function XX
  • ‒ Press keys -0- and -6- to end the output.
 
→ Indicated on display:
Rapid data transfer     Q
06 End output
  • ‒ Confirm entry with the Q key.
 
→ Indicated on display:
Rapid data transfer     HELP
Enter address word XX
  • ‒ Switch off ignition.
  • ‒ Disconnect connector to fault reader V.A.G 1551.

Removing and installing batteries for the main key with radio wave remote control > < Matching ignition keys to radio wave remote control