Evaluating measured value blocks, display groups 70...89 -Reducing emissions-
Evaluating measured value blocks, display groups 70...89 -Reducing emissions-
Display group 70 -Reducing emissions- Activated charcoal filter system diagnosis (tank breathing system)
|
▪ Engine running at idling speed
|
▪ Coolant temperature at least 40 °C
|
▪ Control unit in mode 04-Basic settings
|
Read measured value block 70
|
⇒
|
◂ Indicated on display
|
|
|
xxx %
|
xx.x %
|
|
Text
|
|
|
|
1
|
2
|
3
|
4
|
◂ Display zones
|
Specification
|
Evaluation
|
|
|
|
|
Result of diagnosis (Test ON / OFF or TBV OK / n.OK)
|
TBV OK
|
---
|
|
|
|
|
|
|
|
|
Lambda regulation deviation in TVV diagnosis
|
---
|
---
|
|
Activated charcoal filter system solenoid valve 1 duty cycle
|
0...100 %
|
---
|
Note:
TBV means fuel tank breathing valve (activated charcoal filter system solenoid valve 1). The diagnosis can only be initiated once per engine start.
Notes on display zone 2:
-
◆ Lambda regulator deviation in negative range: Activated charcoal filter full
-
◆ Lambda regulator deviation in positive range: Activated charcoal filter empty
|