| Hang radiator on workshop hoist -V.A.G 1202/A- and lifting tackle -VAS 2024A- using workshop material (cable ties or uncoated wire) and unhook radiator from lock carrier. Coolant hoses and refrigerant lines remain connected. |
–
| Remove securing bolt -2- and remove retaining clip. |
WARNING Danger of freezing injuries. |
If refrigerant circuit has not been evacuated, refrigerant will escape. |
Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in coolant circuit due to re-evaporation. Extract refrigerant again. |
|
–
| Remove bolts -1- and pull out receiver with dryer upwards. |
Note Depending on condenser, only one bolt -1- may be present. |
|
|
|