Checking exhaust gas recirculation valve (mechanical) |
Special tools and workshop equipment required |
t
| Hand vacuum pump with accessories -V.A.G 1390- |
–
| Pull vacuum hose off exhaust gas recirculation valve. |
–
| Connect hand vacuum pump with accessories -V.A.G 1390- to valve. |
–
| Operate pump and observe diaphragm rod. |
|
|
|