t
| Vacuum tester -V.A.G 1368- |
l
| The variable intake manifold change-over valve -N156- was checked with vehicle diagnosis tester in “Guided fault finding”. |
If the variable intake manifold change-over valve -N156- is OK, perform the following tests: |
–
| Check that vacuum lines are connected correctly. |
–
| Check vacuum hoses for porosity. |
–
| Check vacuum system for leaks. |
–
| Check vacuum unit in intake manifold upper part for leaks → Chapter. |
|
|
|