volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Dealing with problems with MidtronicsINC 940 battery tester > < General description of MidtronicsINC 940 battery tester
Charging battery
Charging battery
Prerequisites:
  WARNING
It is not permissible to test or charge batteries whose magic eye shows light yellow. Do not slave/jump start the vehicle!
Danger of explosion when checking and charging or slave/jump starting.
These batteries must be renewed.
INC 940 initial setup performed (dealership number, date/time) → operating manual INC 940.
–  Check general information → Chapter.
–  Open bonnet or cover for other installation location of battery.
–  Perform visual check of battery → Chapter.
–  Determine whether battery type is „Standard“ (wet battery) or „AGM“ (absorbent glass mat battery).
–  Close all vehicle doors.
  Note
t  Battery temperature must be at least 10 °C.
t  For additional information, refer to the → operating manual INC 940.
Perform charging procedure:
–  Switch off all electrical consumers.
–  Switch off ignition and remove ignition key.
–  Connect red terminal clamp „+“ of charger unit to positive terminal on battery.
  Note
In vehicles with start/stop function and battery monitor control unit -J367- fitted, black terminal clamp must be connected to body earth. Connecting it to battery negative terminal will cause start/stop system to malfunction.
–  Connect black terminal clamp „-“ of battery charger to negative terminal.
–  Connect Midtronics -INC 940- battery charger to an earthed socket.
–  Set „ON/OFF“ switch of Midtronics -INC 940- battery charger to „ON“.
–  Select „Automatic“ or „Manual“ charging mode.
–  Select test „In vehicle“ or „Outside vehicle“.
–  Select battery type „Standard “ or „AGM“ (absorbent glass mat).
–  Select test type „Warranty“ or „Miscellaneous“. Note additional details (depending on type of test).
  Note
t  For additional information, refer to the → operating manual INC 940.
t  If necessary, make a note of menu items required for „Warranty“ test type → Warranty service circular.
Midtronics -INC 940- battery charger tests battery and starts charging procedure. Display then shows one of three results, as well as approximate charging time.
   
Result:Measures:
Battery OKBattery can be returned to operation.
Charging required
t  Test found low charge level.
t  Charging starts and approximate charging duration is displayed.
t  Achieved cold-start performance and remaining charging time are displayed, and are updated regularly.
Renew battery.Battery defective. Charging procedure is interrupted. Renew battery.

  Note
In case Midtronics -INC 940- shows fault messages or text displays other than those listed above, please refer to → Chapter.
  WARNING
Stop charging if battery is emitting a lot of gas. Press „Stop“ button on front.
When charging and testing procedure has finished, Midtronics -INC 940- battery charger displays „Battery good“ or „Renew battery“ and total charging time.
There are three possible messages depending on individual circumstance (printout for warranty, repair job, evaluation and filing):
t  Generate test code (only possible after automatic charging and test).
t  Print last test result (for warranty).
t  Display last test results.
  Note
For additional information, refer to the → operating manual INC 940.
   

Dealing with problems with MidtronicsINC 940 battery tester > < General description of MidtronicsINC 940 battery tester