WARNING It is not permissible to test or charge batteries whose magic eye shows light yellow. Do not slave/jump start the vehicle! |
Danger of explosion when checking and charging or slave/jump starting. |
These batteries must be renewed. |
|
–
| Open bonnet or cover for other installation location of battery. |
–
| Determine whether battery type is „Standard“ (wet battery) or „AGM“ (absorbent glass mat battery). |
–
| Close all vehicle doors. |
Note t
| Battery temperature must be at least 10 °C. |
Perform charging procedure: |
–
| Switch off all electrical consumers. |
–
| Switch off ignition and remove ignition key. |
–
| Connect red terminal clamp „+“ of charger unit to positive terminal on battery. |
Note In vehicles with start/stop function and battery monitor control unit -J367- fitted, black terminal clamp must be connected to body earth. Connecting it to battery negative terminal will cause start/stop system to malfunction. |
–
| Connect black terminal clamp „-“ of battery charger to negative terminal. |
–
| Connect Midtronics -INC 940- battery charger to an earthed socket. |
–
| Set „ON/OFF“ switch of Midtronics -INC 940- battery charger to „ON“. |
–
| Select „Automatic“ or „Manual“ charging mode. |
–
| Select test „In vehicle“ or „Outside vehicle“. |
–
| Select battery type „Standard “ or „AGM“ (absorbent glass mat). |
–
| Select test type „Warranty“ or „Miscellaneous“. Note additional details (depending on type of test). |
Note Midtronics -INC 940- battery charger tests battery and starts charging procedure. Display then shows one of three results, as well as approximate charging time. |
|
|
|