Golf Mk6
Installing |
l | Guide element is pushed into side panel. |
– | Pass water drain hose -4- through aperture in tank flap unit and pull water drain hose through as far as possible. |
– | Guide water drain hose -4- into side panel. |
– | With hinge side leading, guide tank flap unit -1- into side panel -arrow a-. |
– | Then swivel tank flap unit completely into side panel -arrow b-, ensuring that locking lugs engage correctly in side panel. |
– | Pull rubber grommet -2- over fuel filler neck -3- and tighten bolt. |
Specified torque for bolt -5-: 1.5 Nm |