volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 2845 > < Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 2843
Page 6
background image

If the display in display zone 2 remains constantly at a value:

-

Continue check according to following table.

If the Oxygen sensor control in display zone 1 does not fluctuate as stated:

-

Press -> key.

-

Press keys 0 and 6 for "End data transfer" function and confirm input with Q key.

-

Carry out road test and bum Oxygen sensors clean and repeat check.

Observe the valid safety precautions when carrying out a road test. See: Fuel Delivery and Air Induction/Fuel Injector/Service Precautions/Technician
Safety Information 

If the the specifications in display zone 1 are not obtained even after a test drive, or the value does not fluctuate by at least 2%:

-

Replace Oxygen sensor before catalyst (G39).

Checking basic voltage

-

Remove protective cover -arrows- and separate 4 pin connector (black) to Oxygen sensor before catalyst (G39).

Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 2845 > < Oxygen Sensor (O2S) Aging Oxygen Sensor 1, Checking|Page 2843