Disconnect 4-pin connector from Manifold Absolute Pressure (MAP) Sensor -G71- with IAT Sensor -G72- (arrow)

-

Measure resistance between sensor terminals 1 + 2

-

Specification: correlate resistance measurement with chart

NOTE:  Scale A shows resistance values for temperature range 0 to 50 °C and scale B shows the values for temperature range 50 to 100 °C.

Examples:

-

30 °C corresponds to a resistance from 1500 to 2000 ohms

-

80 °C corresponds to a resistance from 275 to 375 ohms