EGR Temperature Sensor: Testing and Inspection

Check With VAG 1551 Scan Tool In "Read Measuring Value Block" Function, Testing Closed Throttle Position.

-

VAG 1551 Scan Tool connected with "Read Measuring Value Block" Function Selected Display Group 02.

Indicated On Display:

Read Measuring Value Block 2

1       2       3       4

-

No leaks in vacuum lines and hose connections

-

Vacuum lines not plugged or kinked

-

Engine oil temperature min. 50°C (122°F)

-

Disconnect EGR Vacuum Regulator Solenoid Valve (N18) -1-.

-

Connect VAG 1390 vacuum pump to the disconnected hose.

-

Operate vacuum pump.
-

Performance at Closed Throttle Position must get noticeably worse.

If NO:

-

Check lines and connections for obstructions and clean if necessary.

-

If necessary, Replace EGR Valve.

If Idle Gets Worse:

-

Read EGR temperature in display field 4. Temperature must rise steadily without interruption.

-

If display reads 127.4°C, or if the temperature drops, there is an interruption.

-

As soon as the temperature value reaches 200°C, disconnect vacuum pump.

-

Press -> button.

-

Press buttons -and -6- for "End Output" Function.

-

Press -Q- button to confirm input.

If no fault is found:

-

Replace EGR Temperature Sensor (G98).