volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

High Pressure Safety Valve HVAC > < Heating and A/C Unit, Removing/Assembly|Page 7482
Page 2
background image

2

-

Self tapping screw
-

Use if retainer clips break

3

-

Air distribution housing

4

-

Servo motor for - fresh/recirculating air door -V154-

5

-

Self tapping screw

6

-

Fresh air blower -V2-

7

-

Cover

8

-

Self tapping screw

9

-

Series resistor -N24-

10

-

Sheet metal screw

11

-

Central flap lever

12

-

Temperature flap lever

13

-

Base plate

14

-

Heater core/bulkhead seal

Heater Core/Bulkhead Seal, Installation Position

Heater core/bulkhead seal, installation position

The seal between the heater core and the bulkhead has a positioning mark.

-

Install seal -1- so that the notches on the seal and the base plate -2- align -3-.