Golf L4-2.0L (AEG) (1999)
-
Operate hand vacuum pump.
Valve must open
If combination valve does not open:
-
Replace combination valve.
Engines: AEG, AVH, AZG, BBW and BEV
Requirements
-
No malfunctions stored in DTC memory
-
Final control diagnosis performed, Adapting functions and components.
-
Vacuum lines and hose unions must not leak.
Work sequence
Note:
Do not use compressed air during the following check!
-
Remove engine cover.
-
Remove pressure hose (arrow) from secondary air pump motor.
Note:
Press buttons on hose couplings together to release coupling.
-
Blow lightly into pressure hose to combination valve.
Combination valve must be closed.
-
Blow forcibly into pressure hose to combination valve.
Combination valve must open
It combination valve does not open or is continually open:
-
Replace combination valve.
With Generic Scan Tool
Combination Valve, Checking (Vehicles with engine code AEG)
Special tools
-
V.A.G 1390 Hand vacuum pump
Test requirements
-
Vacuum lines and seals not leaking
-
Vacuum lines not clogged or crimped
-
Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked
Test procedure
Note:
Do not use pressurized air for the following test!
-
Remove front noise insulation.