volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Combination Valve, Checking|Page 4336 > < Combination Valve, Checking|Page 4334
Page 3
background image

-

Operate hand vacuum pump.
Valve must open

If combination valve does not open:

-

Replace combination valve.

Engines: AEG, AVH, AZG, BBW and BEV

Requirements

-

No malfunctions stored in DTC memory

-

Final control diagnosis performed, Adapting functions and components.

-

Vacuum lines and hose unions must not leak.

Work sequence

Note:

Do not use compressed air during the following check!

-

Remove engine cover.

-

Remove pressure hose (arrow) from secondary air pump motor.

Note:

Press buttons on hose couplings together to release coupling.

-

Blow lightly into pressure hose to combination valve.
Combination valve must be closed.

-

Blow forcibly into pressure hose to combination valve.
Combination valve must open

It combination valve does not open or is continually open:

-

Replace combination valve.

With Generic Scan Tool

Combination Valve, Checking (Vehicles with engine code AEG)

Special tools

-

V.A.G 1390 Hand vacuum pump

Test requirements

-

Vacuum lines and seals not leaking

-

Vacuum lines not clogged or crimped

-

Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked

Test procedure

Note:

Do not use pressurized air for the following test!

-

Remove front noise insulation.

Combination Valve, Checking|Page 4336 > < Combination Valve, Checking|Page 4334