Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data 

-

Generate readiness code.   See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes 

If specified value is obtained:

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring
Test 

Vehicles with engine code AEG

-

Check wire between test box socket 15 + 2-pin connector terminal 2 for open circuit according to wiring diagram. Wire resistance: max: 1.5 Ohms

Vehicles with engine code AVH, AZG

-

Check wire between test box socket 64 + 2-pin connector terminal 2 for open circuit according to wiring diagram. Wire resistance: max: 1.5 Ohms

Continuation for all vehicles

-

Also check the wire for short circuit to B+ and Ground (GND). Specified value: Infinite Ohms

-

Check wire between 2-pin connector terminal 1 and the Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram. Wire resistance:
max: 1.5 Ohms

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.