volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Steering Column Switch, Through 05.10, Assembly Overview|Page 3187 > < Steering Column Switch, Through 05.10, Assembly Overview|Page 3185
Page 3
background image

Installing:

CAUTION!
The turn signal lever could break when installing the control module. 

The turn signal lever must be in the 0 position when installing the spiral spring so that it does not fall out.

Install in reverse order of removal, noting the following:

-

Mount the Steering column electronic systems control module on the steering column switch making sure it is straight until it latches.

-

Install the bolt for the Steering column electronic systems control module on the steering column switch module and tighten it to 1.5 Nm.

-

Install all components in reverse order of removal.

Steering Column Electronic Systems Control Module, Valeo With KESSY

Steering Column Switch, from 06.10

Steering Column Electronic Systems Control Module, Valeo with KESSY

Removing:

CAUTION!
The removal and installation of individual steering column switch components must be done in the specified sequence. Refer to => [
Steering Column Switch Components with KESSY ].
 See: Steering Mounted Controls Communication Module/Service and Repair/Steering
Column Switch, From 06.10/Steering Column Switch Components With KESSY

CAUTION!
‹› The airbag could deploy.

‹› The airbag could deploy if the airbag unit is handled incorrectly. 

‹› Observe safety precautions when working on the airbag.

-

Disconnect battery. Refer to => [ Battery, Disconnecting and Connecting ] See: Starting and Charging/Tools and Equipment/Battery,
Disconnecting and Connecting. 

Remove the following components in order:

-

Remove steering wheel.

-

Remove steering column trim.

-

Disconnect the connectors - 1 -, - 2 -, -  3 - and - 4 -, depending on the vehicle equipment level. 

Steering Column Switch, Through 05.10, Assembly Overview|Page 3187 > < Steering Column Switch, Through 05.10, Assembly Overview|Page 3185