If the specified values are not obtained:

-

Press -> button.

-

Press buttons -0- and -6- to select "End Output" function 06 and press -Q- button to confirm input.

-

Turn off ignition.

-

Remove protective cover (arrows) and disconnect 4-pin harness connector (black) -1- from Heated Oxygen Sensor (HO2S) -G39- before Three
Way Catalytic Converter (TWC).

-

Check oxygen sensor heater for continuity at oxygen sensor harness connector terminals 1 and 2.

NOTE:  The heating element resistance is approx. 1-5 ohms at room temperature. Even slight increases in room temperature can increase the resistance
greatly.

If it is determined that oxygen sensor heater has an open circuit:

-

Replace Heated Oxygen Sensor (HO2S) -G39- before Three Way Catalytic Converter (TWC). Refer item 32, See: Fuel Delivery and Air
Induction/Locations 

-

Check DTC memory. If necessary, repair any malfunctions and erase DTC memory.
See: Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic Trouble Codes
See: Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Clearing Diagnostic Trouble Codes

  

-

Display readiness code.   See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes  
If DTC memory has been erased, or the Engine Control Module (ECM) was disconnected from permanent battery (B+) voltage, generate the
readiness code again.   See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If oxygen sensor heater has continuity:

Checking voltage supply