Check wiring between test box and 4-pin harness connector for open circuit according to wiring diagram (terminal -2- + socket 28).
Wire resistance: max. 1.5 ohms

If the specified value is obtained:

-

Check wire between 4-pin harness connector terminal -1- and Fuel Pump (FP) relay -J17- for open circuit according to wiring diagram.
Wire resistance: max. 1.5 ohms

With Generic Scan Tool

Oxygen Sensor And Oxygen Sensor Control Behind Three Way Catalytic Converter (TWC), Checking

NOTE:

-

Vehicle must be raised before connector for oxygen sensor is accessible.

-

When servicing terminals 3 and 4 in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.

Recommended special tools and equipment

-

VAG1526 multimeter or VAG1715 multimeter

-

VAG1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G130- must be OK.

-

Battery voltage must be at least 11.5 volts.

-

All electrical consumers like, for example, lights and rear window heating must be switched off.

-

Parking brake must be engaged or else daylight driving lights will be switched on.

-

For vehicles with automatic transmission, selector lever must be in position -P- or -N-.

-

If vehicle is equipped with an A/C system, it must be switched off.

-

Ground (GND) connections between engine and chassis must be OK.

-

Exhaust system must be properly sealed between catalytic converter and cylinder head.

-

Coolant temperature must be at least 80 degree C, Diagnostic mode 1: Check measuring values; PID 5, Coolant temperature. See: Testing and
Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 1: Check Measured Values 

-

Oxygen sensor heater for oxygen sensor behind catalytic converter must be OK,

Function test

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached, Diagnostic mode 5: Check output

Oxygen Sensor Before Catalyst|Page 3538 > < Oxygen Sensor Before Catalyst|Page 3536