Golf GL L4-2.0L (AEG) (2001)
of oxygen sensor signals. See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check
Output of Oxygen Sensor Signals
If specified values are obtained:
-
End diagnosis and switch ignition off.
If specified values are not obtained:
-
End diagnosis and let engine continue to run at idle.
-
Check primary voltage.
Checking primary voltage
-
Unscrew protective cover (arrows) and disconnect 4-pin harness connector (brown) -1- to Oxygen Sensor (O2S) behind Three Way Catalytic
Converter (TWC) -G130-.
-
Connect multimeter for voltage measurement to terminals 3 + 4 of connector to Engine Control Module (ECM) and measure primary voltage.
Specified value: 0.400 to 0.500 Volts
-
Switch ignition off.
If specified value is not obtained:
-
Test oxygen sensor wires.
If specified value is obtained:
-
Replace Oxygen Sensor (O2S) 2 Bank 1 Behind Three Way Catalytic Converter (TWC) -G130-:
-
Vehicles with engine code AEG, item 10,
-
Vehicles with engine code AVH, AZG, item 13.
-
Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Testing and Inspection/Scan Tool
Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data
-
Generate readiness code. See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes
Checking oxygen sensor wires
-
Connect test box to control module wiring harness, connect test box for wiring test. See: Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test
Vehicles with engine code AEG