volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Combination Valve, Checking|Page 4013 > < Combination Valve, Checking|Page 4011
Page 4
background image

-

Disconnect vacuum hose -1- from Secondary Air Injection solenoid valve -N112 -2-.

-

Connect V.A.G 1390 hand vacuum pump to vacuum hose -1-.

-

Disconnect pressure hose at Secondary Air Injection (AIR) pump motor (arrow) and blow into it with light pressure. Combination valve must
close.

Note:

To disengage, compress the buttons at the hose coupling.

-

Operate vacuum pump. Combination valve must open.

If the combination valve does not open or it is constantly open:

-

Replace combination valve.

Combination Valve, Checking|Page 4013 > < Combination Valve, Checking|Page 4011