Golf GL L4-2.0L (AEG) (2001)
-
Disconnect vacuum hose -1- from Secondary Air Injection solenoid valve -N112 -2-.
-
Connect V.A.G 1390 hand vacuum pump to vacuum hose -1-.
-
Disconnect pressure hose at Secondary Air Injection (AIR) pump motor (arrow) and blow into it with light pressure. Combination valve must
close.
Note:
To disengage, compress the buttons at the hose coupling.
-
Operate vacuum pump. Combination valve must open.
If the combination valve does not open or it is constantly open:
-
Replace combination valve.