Disconnect 2-pin connector from secondary air inlet valve (arrow).

-

Connect voltage tester VAG 1527B to the outer contacts of connector with auxiliary cables from V.A.G 1594C.

-

start engine and run at idling speed.
The LED must light up.

LED lights up (voltage supply OK.):

-

Replace secondary air inlet valve.

LED does not light up.

-

Connect 2-pin connector

-

Check activation of valve.   See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Manufacturer's
Scan Tool/Output Diagnostic Test Mode (DTM), (Function 03)

-

Check wiring, refer to wiring diagrams

-

Read DTC memory   See: Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading
Diagnostic Trouble Codes

-

Read readiness code:   See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

-

Generate readiness code again if DTC memory has been erased or engine control module was disconnected from permanent positive.   See:
Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes