Possible causes of malfunction if O2S sensor control frequency is too slow:
-
The slots or holes in O2S sensor body are blocked.
-
The O2S sensor vent hole in area of connecting wire is blocked.
-
The O2S sensor has been overheated (glazed).
-
The O2S sensor has been damaged by leaded fuel.
Checking basic voltage for oxygen sensor 2
-
Remove protective cover (arrows) and disconnect 4-pin harness connector (brown) -1- to oxygen sensor after Three Way Catalytic Converter
(TWC) -G130-.