volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Before Catalyst|Page 3478 > < Oxygen Sensor Before Catalyst|Page 3476
Page 14
background image

Indicated on display: (1-2 = display fields)

Read Measuring Value Block 33 

->

1

2

-

Observe Oxygen Sensor (O2S) control in display field 1.

-

Check oxygen sensor voltage in display field 2.

Display Group 33

Notes on display field 2:

-

The voltage signal "rich mixture (low level of residual oxygen)" is approx. 0.7-1.0 V.

-

The voltage signal "lean mixture (high level of residual oxygen)" is approx. 0.0-0.3 V.

-

When changing from "rich" to "lean" and back again (Lambda = 1.0) the voltage jump will change from 0.7-1-0 V to 0.0-0.3 V or back again.

-

Due to steep voltage jumps, the oxygen sensor control cannot keep the ideal mixture composition (lambda = 1.0) constant. The control fluctuates
constantly between a "slightly too lean" and "slightly too rich" condition.

Oxygen sensor voltage U Lambda in mV

Oxygen Sensor Before Catalyst|Page 3478 > < Oxygen Sensor Before Catalyst|Page 3476