Possible causes of malfunction if oxygen sensor control frequency is too slow:
-
The slots or holes in O2S sensor body are blocked
-
The O2S sensor vent hole in area of connecting wire is blocked
-
The O2S sensor has been overheated (glazed)
-
The O2S sensor has been damaged by leaded fuel
Checking oxygen sensor basic voltage
-
Remove protective cover (arrows) and disconnect 4-pin harness connector (black) -1- from Heated Oxygen Sensor (HO2S) -G39- before Three
Way Catalytic Converter (TWC).