background image

Terminal 2 + socket 63
Wire resistance: max: 1.5 Ohms

Continuation for all vehicles

-

Also check wires for short circuit to B+ and Ground (GND). Specified value: Infinite Ohms

-

Check wire between 4-pin connector terminal 1 and Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohms

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.

With Manufacturer's Scan Tool

Oxygen sensor heater for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-, checking

Special tools and equipment

-

V.A.G1551 scan tool (or VAG1552 mobile scan tool) with VAG1551/3 cable

-

VAG1598/31 test box

-

Multimeter Fluke 83 or equivalent

-

VAG1594 connector test kit

-

Wiring diagram

Test requirements

-

All fuses must be OK.

-

Battery voltage must be at least 11.5 volts.

-

Fuel Pump (FP) relay must be OK.

Test sequence

-

Connect VAG1551 scan tool (VAG1552). Start engine and select the Engine Control Module (ECM) using address word 01.   See: Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting

Indicated on display:

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -8- to select "Read measuring value block" function 08. Press -Q- button to confirm input.

Indicated on display:

Read measuring value block
Enter display group number XXX

-

Press buttons 4-, -0- and -1- to select "Display group number 41". Press -Q- button to confirm input.

Oxygen Sensor Before Catalyst|Page 3216 > < Oxygen Sensor Before Catalyst|Page 3214