Range A displays resistance values for the temperature range of 0 to 50 degree C, range B displays resistance values for the temperature range of 
50 to 100 degree C.

Read-out examples:
-

30 degree C is in range A and corresponds to a resistance of 1.5 to 2.0 kOhms

-

80 degree C is in range B and corresponds to a resistance of 275 to 375 Ohms

If specified value is not obtained:

-

Replace Engine Coolant Temperature (ECT) sensor -G62-.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Powertrain Management/Computers
and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase
Diagnostic Data

-

Generate readiness code.   See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles
and Readiness Codes 

If no malfunctions are detected in the wires and the resistance values are OK:

-

Replace Motronic Engine Control Module (ECM) -J220-.