CAUTION

Inductive pickup (on VW 1367) must NOT be connected.

-

remove connector (2) of auxiliary air regulator (1) and connect it to connector (3) of the remote control US 4480/3 -connect alligator clip (4) to
battery (+)

Duty Cycle Valve, Control Unit

Duty cycle valve, checking

-

operate switch on remote control US 4480/3

^

duty cycle valve must audibly click

If duty cycle valve clicks, continue with test (B) (checking control unit)

If duty cycle valve does not click, perform the following test

-

remove connector from duty cycle valve -check prongs of the connector and of the duty cycle valve for correct positioning (must not be damaged