volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

All Other Service Bulletins for Oxygen Sensor:|258502 > < Oxygen Sensor System - Checking|Page 4250
Page 4
background image

Rich-limit testing (tester reading increases)

^

US 4480/3 switched ON

^

OXS thermoswitch connector unplugged (if engine cold)

-

unplug oxygen sensor at connection and ground green wire

-

check reading displayed on VW 1367

^

must be at least 87% (78~ dwell)

If reading NOT OK
-

check for open circuit in wiring to OXS control unit

If wiring OK
-

replace OXS control unit

If reading OK
-

continue with lean-limit testing

Oxygen sensor, checking

^

switch of US 4480/3 ON

^

thermoswitch connector removed

-

disconnect crankcase ventilation hoses 2 and 3 and vent to atmosphere

-

reconnect wire to oxygen sensor

-

reconnect coil wire into distributor cap

-

start engine and hold at 2500 rpm for more than two minutes

Note

After engine running more than two minutes, exhaust gas will warm sensor and it will start to work (reading fluctuates)

-

check reading on tester at idle speed (idle speed must be within specifications)

^

reading on tester must fluctuate

If reading NOT OK (constant at 13% or 87% [12~ or 78~ dwell])
-

CO may be out of specs. See Repair Group 25, Product Circular 85-02

If reading is a steady 50% (45~ dwell) or constant at specification limits and OXS control unit OK
-

replace oxygen sensor

-

reconnect thermoswitch connector

-

reinstall crankcase breather hoses

-

remove US 4480/3

All Other Service Bulletins for Oxygen Sensor:|258502 > < Oxygen Sensor System - Checking|Page 4250