Page 7
background image

Display Group: 036 Display Field: 2

-

Slowly open throttle valve and watch angle display in display field 3.

-

The value must increase uniformly over the complete range.

-

Press -> button.

-

Press buttons -0- and -6- to select "End Output" function 06 and press -Q- button to confirm input.

-

Switch ignition off.

NOTE:

The displayed value is dependent on the tolerances of the Throttle Position sensor and does not correspond to the actual opening angle. The maximum
permissible displayed value is 90.0 <°.

If the value does not increase uniformly:

-

Replace throttle valve control module -J338-.

-

Read the readiness code, If DTC memory has been erased, repair must be verified via appropriate display group: Readiness code, creating.

Evaluating Display Group 003

Check Wiring

-

Connect VAG 1598/18 test box to ECM wiring harness.

-

Connect multimeter using test leads from VW 1594 to measure resistance attest box sockets 01 and 40 and check wiring for short circuit to
Ground.
Specification: Infinite Ohms 

-

Set multimeter to voltage measurement range.

-

Switch ignition on.

-

Check wiring for short circuit to positive (B+). If necessary, note voltage value.

Diagram Information and Instructions|Page 3472 > < Diagram Information and Instructions|Page 3470