Golf GTI V6-2792cc 2.8L DOHC (AAA) SFI (1998)
-
Connect multimeter using test leads from VW 1594 to measure voltage at connector terminals 1 and 5.
-
Switch ignition on.
-
Measure voltage between terminals 1 and 5.
Specification: 9-14.5 volts.
-
Switch ignition off.
If the specification is not attained:
-
Check wiring between 5-pin connector terminal 1 and Ground (GND) according to wiring diagram.
Resistance max. 1.5 ohms
-
Check wiring between 5-pin connector terminal 5 and relay panel for open circuit according to wiring diagram.
Resistance: max. 1.5 ohms.
Checking activation
-
Remove fuse 18.
WARNING: During the following test do not touch the terminals of the ignition coil or test leads.
-
Switch ignition off.