volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 5400 > < Symptom Related Diagnostic Procedures|Page 5398
Page 4
background image

- Multimeter Fluke 83 or equivalent

- Switch ignition off.

- Disconnect battery Ground (GND) strap.

After a waiting period of at least 2 hours, during which the battery must not be loaded or charged:

- Measure battery voltage using multimeter.

The battery no load voltage must be lower than 12.5 V.

If the multimeter displays 12.5 V or more the battery voltage is OK.

If the multimeter displays a battery voltage below 12.5 V:

- Charge battery.

After a waiting period of at least 2 hours, during which the battery must not be loaded or charged:

- Measure battery voltage using multimeter.

The battery no load voltage must be lower than 12.5 V.

- If battery no load voltage is not OK, replace battery.

Sealed Battery Voltage Test

Test Conditions:
-

Engine NOT Running.

-

Test for sealed batteries only.

-

Turn headlights on high beam for 1 minute to remove surface charge.

-

Disconnect battery Ground (GND) strap.

-

Check Battery Positive Voltage (B+) using SUN VAT 40 or equivalent.

-

12.5 Volts minimum.

Voltage: 

% Charge:

12.6 or more 

100 %

12.5 

75 %

12.2 

50 %

12.0 

25 %

11.7 or less 

0 %

If above the minimum voltage (12.5 V):
-

Load test battery.

If below the minimum voltage:
-

Charge battery (12.5 V) See: Service and Repair (Charging Battery(ies).)

Specific Gravity

Specific gravity, checking

Special tools and equipment

Symptom Related Diagnostic Procedures|Page 5400 > < Symptom Related Diagnostic Procedures|Page 5398