Page 1
background image

Control Assembly: Adjustments
Without A/C

Main shut-off flap cable
-

Connects blower control knob to main shut-off flap

-

Black sleeve

-

Length: 807 mm (31.8 in.)

Temperature flap cable
-

Connects temperature control knob to temperature flap

-

Blue sleeve

-

Length: 585 mm (23.0 in.)

Footwell/defroster flap cable
-

Connects air flow distribution knob (upper control lever) to footwell/defroster flap

-

Black sleeve

-

Length: 488 mm (19.2 in.)

Central flap cable
-

Connects air flow distribution knob (lower control lever) to central flap

-

Black sleeve

-

Length: 639 mm (25.2 in.)

Adjusting Main Shut-Off Flap Cable

Adjusting main shut-off flap cable

-

Adjust fresh air blower switch (E9) to stop at position "0".

-

Connect main shut-off flap cable (black sleeve) to main shutoff flap lever.

-

Push lever in direction of arrow to stop.

-

Hold lever in this position and install cable retaining clip.