volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

A/C - No Cooling/Compressor Seized|Page 10877 > < A/C - No Cooling/Compressor Seized|Page 10871
Page 1
background image

Condenser HVAC: Customer Interest
A/C - No Cooling/Compressor Seized

Condition

87 07 10 

Aug. 23, 2007 

2013314 Supersedes T.B. Group 87 number 07-08 dated July 26, 2007 Supersedes T.B. Group 87 number 07 03 dated Feb. 15, 2007 due to warranty
table information change.

Air Conditioning Inoperative

Air conditioning does not cool, air conditioning compressor may seize.

Note:

Failure of compressor does not compromise driver visibility.

Vehicles with Zelex/Valeo air conditioning compressors only.

Tip:

Zelex/Valeo compressor can be recognized by the pulley (illustration 1).

Technical Background

Failure Mode Analysis:

There may be more than one concern with Zelex/Valeo air conditioning compressors that will render the air conditioning system inoperative:

1.

The limiter (overload protection against seizing of the pulley), Part number 1K0820803 L and N, is broken or is missing (illustration 1, pos.1).

2.

The compressor control valve, Part number 1K0820803 L and N, is restricted by metal particles and the compressor does not build up pressure.

Production Solution

Final production countermeasure pending.

Service

1: Limiter Broken

A/C - No Cooling/Compressor Seized|Page 10877 > < A/C - No Cooling/Compressor Seized|Page 10871