volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Control Module and Hydraulic Unit (Mark 70 (ABS/ASR))|Page 3292 > < Control Module and Hydraulic Unit (Mark 70 (ABS/ASR))|Page 3290
Page 3
background image

-

For this reason, secure hydraulic pump to hydraulic unit using red retainer - 1 - from replacement part set and two sealing plugs - 2 -.

-

Carefully disconnect hydraulic unit with hydraulic pump upward at interface - 1 - from control module.

When removing control module, be sure that the valve domes of the hydraulic unit do not jam or get bent in the magnetic coils of the control module.

Item 2 pump motor adapter.

-

Cover control module magnetic coils with a lint free cloth.

After separating the control module and hydraulic unit, use transport protection for valve body.

Installing, New Control Module

CAUTION!

Excessive shaking (e.g. dropping, impact) may destroy the control module. Control module must then no longer be used.

^

Before new control module can be assembled, pump motor adapter must first be inserted until it stops and engages. Adapter guide must not be
damaged.

^

The adapter supplied as replacement part for control module can be engage only once and then must not be separated again.

^

The white grouting compound on base of control module serves as a seal and must not be removed.

^

All contact surfaces on adapter, pressure sensor and control module as well as silicon gel and sealing elements must not be touched by hand or
objects, soiled or damaged.

-

Press adapter into adapter guide until it stops, it must then be engaged.

-

Place control module without canting it on to hydraulic unit.

Control Module and Hydraulic Unit (Mark 70 (ABS/ASR))|Page 3292 > < Control Module and Hydraulic Unit (Mark 70 (ABS/ASR))|Page 3290