volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Residual Pressure, Checking|Page 1031 > < Residual Pressure, Checking|Page 1029
Page 2
background image

connection.

-

Disconnect supply line - arrow - and catch escaping fuel using a rag.

NOTE:  Press in securing ring to disengage the fuel lines.

-

Connect pressure gauge V.A.G 1318 with double connection V.A.G 1318/23 and adapter set V.A.G 1318/17 to fuel supply line.

-

Connect hose adapter V.A.G 1318/16 to adapter V.A.G 1318/11 of pressure gauge and hold it in a measuring container.

CAUTION:  Danger of spraying when opening shut-off valve; wear protective goggles and protective clothing to prevent injuries and
contact with skin. Hold container in front of free connection of pressure measuring device.

-

Open shut-off valve of pressure gauge set. Lever will point in direction of flow - A -.

-

Operate remote control V.A.G 1348/3A. Slowly close shut-off tap, until pressure gauge shows 4 bar. From this point on do not move position of
shut-off tap.

-

Empty measuring container.

-

Delivery rate of Fuel Pump is dependent on battery voltage. Connect the Multimeter V.A.G 1715 to connectors - 1 and 5 - on the test instrument
adapter/DSO (5-pin) VAS 5565.

-

Operate remote control for 30 seconds and measure battery voltage.

Residual Pressure, Checking|Page 1031 > < Residual Pressure, Checking|Page 1029