GTI L4-2.0L Turbo (CBFA) (2008)
The linkage - A - must move approximately 300 mbar and be at approximately 700 mbar at end position.
Actuator lift is approximately 10 mm.
NOTE: If pressure cannot be raised with hand vacuum pump VAS 6213 or pressure drops immediately, check hand vacuum pump VAS 6213 and
connecting hoses for leaks. If no malfunction can be found: Replace vacuum diaphragm.