Pull vacuum hose -1-off non-return valve -2-.
-
Connect hand vacuum pump VAG 1390 to non-return valve -2-.
-
Perform Output Diagnosis Test Mode (DTM) again.When the Intake Manifold Change-Over Valve -N156- valve is activated, operate the hand
pump uniformly.The actuating element must switch back and forth between both positions.
If the change-over does not function as described:
-
Check change-over mechanics for freedom of movement. Move the rods by hand.
-
Check vacuum pipes for correct connection.
-
Check the vacuum system including the vacuum reservoir.
NOTE: The vacuum reservoir is bolted below the intake manifold.