background image

-

All fuses must be OK.

-

The battery voltage must be at least 11.5 V.

-

Exhaust system between catalyst and cylinder head must be free of leaks

-

Coolant temperature must be at least 80 °C, See display group 04, display zone 3.

Functional check

-

Connect VAG1551 scan tool (VAG1552). Start engine and select "Address word" 01 of engine control module. When doing this the engine must
be running at idling speed. (Connecting scan tool and selecting engine control module). Refer to "VAG1551 Scan Tool See: Computers and
Control Systems/Tools and Equipment 

Indicated on display:

Rapid data transfer

HELP

Select function XX

-

Press keys 0 and 8 for the function "Read measured value block" and confirm entry with Q key.

Indicated on display:

Read measured value block

HELP

Input display group number XXX

-

Press keys 0, 3 and 0 for the "Display group number 30" and confirm entry with Q key.

Indicated on display: (1 to 4 = Display zones)

Read measured value block 30

->

1

2

3

4

-

Check oxygen sensor control status before catalyst (display zone 1):
Specification: 111

Significance of 3 digit number block in display zone 1:

Oxygen Sensor (O2S) Before Catalytic Converter|Page 2891 > < Oxygen Sensor (O2S) Before Catalytic Converter|Page 2889