Replace oxygen sensor -G130.

-

Check DTC Memory, if necessary, repair any malfunctions and then Erase DTC Memory,Checking and Erasing DTC Memory. Refer to
"Displaying and Reading Trouble Codes/With Manufacture Scan Tool/Check DTC Memory (Function 02)" See: Powertrain
Management/Computers and Control Systems/Testing and Inspection 

-

Read readiness code. If DTC memory has been erased or engine control module was disconnected from permanent positive, readiness code must
be generated again: Refer to "Monitors, Trips and/or Drive Cycle/ Reading Readiness Code" See: Powertrain Management/Computers and Control
Systems/Testing and Inspection 
Engine code AWW, Refer to "Monitors, Trips and/or Drive Cycle/Generating Readiness Code" See: Powertrain Management/Computers and
Control Systems/Testing and Inspection 

Operational Readiness of Oxygen Sensor

Operational Readiness of Oxygen Sensor after Catalyst, Checking

Special tools and equipment

-

VAG1551 scan tool or VAG1552 mobile scan tool with VAG1551/3B cable

Test conditions

-

Coolant temperature must be at least 80 °C, See display group 04, display zone 3.

Functional check

-

Connect VAG1551 scan tool (VAG1552). Start engine and select "Address word" 01 of engine control module. Engine must be running at idling
speed. (Connecting scan tool and selecting engine control module). Refer to "VAG1551 Scan Tool See: Powertrain Management/Computers and
Control Systems/Tools and Equipment 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press keys 0 and 4 for function "Introduction of basic setting" and confirm entry with Q key.

Indicated on display

Basic setting
Input display group number XXX

-

Press keys 0, 3 and 6 for "Display group number 36" and confirm entry with Q key.

Indicated on display: (1...4 = Display zones)

System in basic setting 36

->

1

2

3

4

-

Allow engine to run at idle until readout in display zone 2 jumps from "Test OFF" to "Test ON".

-

Observe oxygen voltage in display zone 1. The value must rise.

Oxygen Sensor (O2S) Before Catalytic Converter|Page 1166 > < Oxygen Sensor (O2S) Before Catalytic Converter|Page 1164