volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Expansion Valve|Description and Operation|Page 6005 > < Expansion Valve|Description and Operation
Page 1
background image

Expansion Valve: Service and Repair

Expansion Valve, Removing/Assembly

NOTE:  

-

Before carrying out any work on the A/C refrigerant system, refer to A/C refrigerant system safety measures.

-

Except where indicated with *, all components illustrated must only be serviced or replaced after discharging refrigerant system. Use Kent Moore
ACR4 or equivalent.

-

O-rings used on R-134a systems may be red, green, violet or black.

-

Always plug open refrigerant line connections to prevent dirt and moisture contamination.

Assembly

1

-

Threaded plate 

2

-

O-ring
-

Always replace

-

10.8 mm; 1.8 mm

3

-

Insulator*

4

-

Bolt
-

8 Nm (71 in. lb)

-

Qty.: 2

5

-

O-Ring
-

Always replace

-

7.6 mm; 1.8 mm

6

-

Bolt

Expansion Valve|Description and Operation|Page 6005 > < Expansion Valve|Description and Operation