volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Testing and Inspection|Page 3261 > < Leak Detection Pump, Evaporative System|Testing and Inspection
Page 2
background image

-

Pull the 3 pin connector off the diagnosis pump (V144).

-

Connect hand multimeter V.A.G 1526 A to measure resistance between the contacts 1 and 3 of -V144. Specification: 640 . . .720 Ohms.

-

Connect hand multimeter V.A.G 1526 to measure resistance between the contacts 2 and 3 of -V144. Specification: 12.5 .. .19.5 Ohms.

If the specifications are not attained:

-

Replace the diagnosis pump -V144

-

Check DTC memory:

-

Read out readiness code:

-

If the DTC memory has been erased or the engine control module separated from the permanent positive, the readiness code must be generated
again.

Checking voltage supply

Test conditions

-

Fuse No. 43 must be OK.

-

The battery voltage must be at least 11.5 V.

Test sequence

-

Remove rear right wheel housing liner: