Check oxygen sensor heater for continuity at connector to Heated Oxygen Sensor (HO2S) terminals 1 + 2.

Vehicles with engine code AWP, AWW

-

Unscrew protective cover (arrows) and disconnect 6-pin harness connector (black) -1- to Heated Oxygen Sensor (HO2S) -G39- before catalytic
converter.

-

Set multimeter for resistance measurement and connect it to terminals 3 + 4 at connector for oxygen sensor. Check oxygen sensor heater for
continuity.
Specified value: 2.5...10 Ohms (at room temperature)

Continuation for all vehicles

If an open circuit is found in the oxygen sensor heater:

-

Replace Heated Oxygen Sensor (HO2S) -G39- Bank 1 before catalytic converter, item 8

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Testing and Inspection/Scan Tool
Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-

Generate readiness code. See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If oxygen sensor heater has continuity:

-

Check voltage supply and wiring

Checking voltage supply and wiring

Vehicles with engine code AWD